video
Ballon PTA pour les lésions BTW

Ballon PTA pour les lésions BTW

PTA Balloon for BTW lesions Intended use of Peripheral Balloon Catheter: Medical Peripheral Angiography Catheter used in the patient's coronary and peripheral vascular, and for a variety of diagnostic and therapeutic medical procedures.

Discuter maintenant
Présentation du produit

Product Overview 

PTA Balloon for BTW lesions come in various sizes, lengths and shapes,  depending on the anatomy they're intended to treat.match with three guidewire system,{{0}}.018 inch, 0.014 inch and 0.035  inch guide wire.  With two different design, coxial and doubel lumen to met different pass-ability and push-ability. 

Utilisation prévue du cathéter à ballonnet périphérique :
Medical Peripheral Angiography Catheter used in the patient's coronary and peripheral vascular, and for a variety of diagnostic and therapeutic medical procedures.

Product Features 


Ballon PTA médical OEM pour les lésions BTW, cathéter de dilatation à ballon PTA Caractéristiques :

  • Advanced laser bonding technology 

  • Technique de formage au laser des pointes

  • Excellente performance de franchissement de la sténose

  • Soft tapered tip 

  • Compense les désalignements et les déviations

  • La cannelure en ballon à 3 ailes

  • le fil à âme conique peut offrir d'excellentes performances de livraison.

PTA-

Product Technical Specification

Compliance                                  

Balloon 

Taille          

Longueur du ballon

Arbre

longueur

Conception de cathéter

Compatibilité du fil guide pouces

SC  PTA Balloon

1,5 mm à 5,0 mm

20-  210mmmm

100/130/150cm

coaxial

0.014

SC  PTA Balloon

2.0-9.0 mm

20-220mm

90/130/180cm

coaxial

0.018

SC  PTA Balloon

2.0-9.0 mm

20-220mm

90/130/180cm

lumière double

0.018

SC  PTA Balloon

2.0-10,0 mm

20-220mm

80/130cm

coaxial

0.035

SC  PTA Balloon

2.0-10,0 mm

20-220mm

80/130cm

lumière double

0.035

NC  PTA Balloon

2.0-5.0 mm

20-220mm

100/150cm

coaxial

0.014

NC  PTA Balloon

2.0-7.0 mm

20-220mm

90/130/180cm

coaxial

0.018

NC  PTA Balloon

2.0-7.0 mm

20-220mm

90/130/180cm

lumière double

0.018

NC  PTA Balloon

2.0-10,0 mm

20-220mm

40/80/130cm

coaxial

0.035

NC  PTA Balloon

2.0-10,0 mm

20-220mm

40/80/130cm

lumière double

0.035

More PTA Balloon for BTW lesions ordering information please contact your sales. 

 Barty Medical Profile 

Zhejiang Barty Medical Technology Co., Ltd. was established in August 2015 in Hangzhou Economic and Technological Development Zone. Engaged in two major lines of cardiovascular, peripheral vascular intervention and implantation. There are currently more than 100 employees in Barty Medical with an average age of 28 years. Company's core members are from internationally renowned foreign medical device companies with working experience more than 15 years.

 

FAQ


1. Q : Pouvons-nous faire des OEM pour le ballon PTA pour les lésions BTW ?

A : Oui, OEM, OBL est disponible.

2. Q : Combien de temps le produit est-il valide ?

R : deux ans

3. Qu'en est-il de l'expédition du cathéter à ballonnet périphérique ?

A: par mer, par DHL, EMS ou autres

4. Q : Combien de temps cela prendra-t-il si j'achète la commande ?

A: selon la quantité dont vous avez besoin.

5. Q: what's the MOQ OF peripheral balloon catheter?

A: dépend de la façon dont nous coopérons et de la demande des différents pays.

Voie de contact

Nom : Amanda Zhu

E-mail:qqzhu@batymedical.com

Mobile: plus 86 157 0559 1759 (whatsapp)


étiquette à chaud: ballon pta pour les lésions btw, Chine, fournisseurs, fabricants, usine, personnalisé, OEM

Envoyez demande

whatsapp

Téléphone

Messagerie

Enquête

sac